Priming and Flushing Storage Fluid (Direct Immersion Method)
Before you use your sprayer for the first time or begin a new spraying project, you need to prime the sprayer and flush the storage fluid out of the sprayer.
Oil- or Water-based Materials
•When spraying
flush the system thoroughly with water.
•When spraying
•To spray
•To spray
•When flushing with solvents, ground gun. Read Grounding and Electric Requirements, page 4.
•To avoid fluid splashing back on your skin or into your eyes, always aim gun at inside wall of pail.
1.Verify AllControl is set to OFF and sprayer is unplugged.
ti9168a
2.Place prime tube in waste pail.
ti9825a
Getting Started
3.Submerge suction tube in flushing solvent.
ti9827a
4.Plug sprayer in grounded outlet.
5.Set AllControl™ to
PRIME/CLEAN PUMP.
ti9169a
6.When sprayer starts pumping,
flushing solvent and air bubbles will be purged from system. Allow fluid to pump out of prime tube, into waste pail, for 30 to 60 seconds.
7.Turn AllControl to OFF.
ti9168a
8.Transfer suction tube to paint pail and submerge in paint.
9.Turn AllControl to
PRIME/CLEAN PUMP.
ti9169a
10.When paint is pumping out of prime tube:
a.point gun into waste pail.
b.unlock gun trigger lock.
c.pull and hold gun trigger.
ti8922a
12 | 312079A |