Storage
Short Term Storage
(up to 2 days)
1.Turn AllControl to OFF. Pause
STORAGE.
Pause
ti9168a | ti9174a |
|
2. Engage trigger lock.
ti8923a
3.Leave gun attached to hose.
4.Remove tip and guard and clean with water or flushing solvent. A soft brush can be used to loosen and remove dried on material if needed.
ti9671a
5.Wipe paint off outside of gun using a soft cloth moistened with water or flushing solvent.
Storage
Long Term Storage
(more than 2 days)
• Always circulate Pump Armor storage fluid through system after cleaning. Water left in sprayer will corrode and ruin pump.
•Follow Shutdown and Cleaning instructions starting on page 20 or 23.
1.HOPPER METHOD: Place prime tube in waste pail. Pour 8 oz. of Pump Armor into hopper.
IMMERSION METHOD: Place suction tube in Pump Armor storage fluid bottle and prime tube in waste pail.
| OR |
| TIA |
Hopper Method | Immersion Method |
2.Set AllControl to
PRIME/CLEAN PUMP.
ti9169a
3.When storage fluid comes out of prime tube
ti9168a
4.Wait
ti9174
312079A | 29 |