Storage

Short Term Storage

(up to 2 days)

1.Turn AllControl to OFF. Pause 2-3 seconds to allow pressure to be relieved, then turn to

STORAGE.

Pause

2-3 Seconds

ti9168a

ti9174a

 

2. Engage trigger lock.

ti8923a

3.Leave gun attached to hose.

4.Remove tip and guard and clean with water or flushing solvent. A soft brush can be used to loosen and remove dried on material if needed.

ti9671a

5.Wipe paint off outside of gun using a soft cloth moistened with water or flushing solvent.

Storage

Long Term Storage

(more than 2 days)

• Always circulate Pump Armor storage fluid through system after cleaning. Water left in sprayer will corrode and ruin pump.

Follow Shutdown and Cleaning instructions starting on page 20 or 23.

1.HOPPER METHOD: Place prime tube in waste pail. Pour 8 oz. of Pump Armor into hopper.

IMMERSION METHOD: Place suction tube in Pump Armor storage fluid bottle and prime tube in waste pail.

 

OR

 

TIA

Hopper Method

Immersion Method

2.Set AllControl to

PRIME/CLEAN PUMP.

ti9169a

3.When storage fluid comes out of prime tube (5-10 seconds) turn AllControl to OFF.

ti9168a

4.Wait 2-3 seconds to allow pressure to be relieved, then turn AllControl to STORAGE.

ti9174

312079A

29

Page 29