Shutdown & Cleaning - After Hopper Method Applications

15.To preserve paint in hose:

a.Point gun into paint pail.

b.Unlock gun trigger lock.

c.Pull and hold gun trig-

ger.

ti8922a

d.Turn AllControl to

PRIME/CLEAN GUN AND HOSE.

ti9171a

e. Continue to hold gun trigger until you see

paint, diluted with water starting to come

out of gun.

16. While continuing to

trigger gun, quickly

move gun to redirect

19.Close Power Flush attachment.

CLOSED

TIA

20.Remove hose extender and Power Flush attachment from hopper.

ti9747a

21.Follow Long Term Storage instructions, page 29.

22.Clip drain tube to hopper.

23.Use a soft brush to clean paint and debris off strainer and install strainer in hopper.

spray into waste pail.

Continue triggering

gun into waste pail until

water coming out of

ti9745a

gun is relatively clear, approximately 1-2 minutes.

17.Stop triggering gun. Engage trigger lock.

ti8923a

24.Clean gun fluid filter (d) with water or flushing solvent and a brush every time you flush the system. Replace gun filter if damaged.

25.Clean tip and guard with water or flushing solvent. A soft brush can be used to loosen and remove dried on material if needed.

d

ti9671a

ti9257a

18. Set AllControlto OFF.

ti9168a

26.Wipe paint off outside of

gun using a soft cloth moistened with water or flushing solvent.

27.Use a soft cloth to wipe off hopper, cover, and hose. Install hopper cover.

ti9126a