Park
ParkFlushing
Park the pumps at the end of the day to cycle compo- nent A pump to home position, submerging displace- ment rod.
1. Open the park valve.
Open | Close |
Flush equipment only in a
•Flush out old fluid with new fluid, or flush out old fluid with a compatible solvent, such as toluene, naptha, or mineral spirits before introducing new fluid.
•Use lowest possible pressure when flushing.
•To flush feed hoses, pumps, and the heater sepa- rately from the heated hoses, set PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCULATION. Flush through bleed lines
(N).
2.Trigger the gun until pumps stops at the bottom and relieves pressure.
3.Close the air motor shutoff valve.
4.Close the park valve.
N
SA
SB
N
ti8441a
•To flush entire system, circulate through gun fluid manifold (with manifold removed from gun).
•Always leave hydraulic oil or a
water.
Only use flush solvents that are compatible with Fluoroelastomer seals.
14 | 3A1570A |