Park

ParkFlushing

Park the pumps at the end of the day to cycle compo- nent A pump to home position, submerging displace- ment rod.

1. Open the park valve.

Open

Close

Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents.

Flush out old fluid with new fluid, or flush out old fluid with a compatible solvent, such as toluene, naptha, or mineral spirits before introducing new fluid.

Use lowest possible pressure when flushing.

To flush feed hoses, pumps, and the heater sepa- rately from the heated hoses, set PRESSURE RELIEF/SPRAY valves (SA, SB) to PRESSURE RELIEF/CIRCULATION. Flush through bleed lines

(N).

2.Trigger the gun until pumps stops at the bottom and relieves pressure.

3.Close the air motor shutoff valve.

4.Close the park valve.

N

SA

SB

N

ti8441a

To flush entire system, circulate through gun fluid manifold (with manifold removed from gun).

Always leave hydraulic oil or a non-water based, non-water absorbent fluid in system. Do not use

water.

Only use flush solvents that are compatible with Fluoroelastomer seals. Non-compatible solvents will damage seals and cause hazardous conditions, such as high pressure leaks and pressure switch failure.