Repair

Repair

Unless otherwise noted, all repair procedures must be completed with incoming power switched OFF and locked out at the source. Any electrical repair or troubleshooting required beyond the scope of this manual must be performed by a qualified electrician. Shut off air inlet ball valve and shut off all air supply pressure.

Disconnect Pump

Air motor shaft, yoke, pump rod and connecting rod move during operation. Moving parts can cause

6.Shut off inlet air ball valve (G)

7.Remove screws (13, 15) and pump covers (63).

13

63

63

15

13

ti17989a

15

8.Disconnect A side (21) and B side (23) steel outlet tubes from adapters (312).

serious injury such as pinching or amputation. Keep hands and fingers away from connecting rod during operation.

NOTE: See manual 309577 for pump repair instructions.

1. Turn main heater power OFF

.

2.

Follow Flushing, page 14.

3.

Follow Pressure Relief Procedure, page 13.

23

312

M

318

M

31221

4.

Follow Park instructions, page 14.

5.

Shut off both feed pumps and close both inlet supply

 

valves (F).

 

 

F

G

F

ti17988a

 

324

317

ti17990a

9.Remove adapter (312) from fluid outlet (M).

10.For A Side pump, disconnect barb fitting (318), elbow fitting (317), and two pipe plugs (324).

NOTE: It is not necessary to cut tubes connected to barb fittings.

22

3A1570A

Page 22
Image 22