Troubleshooting

Before performing any troubleshooting procedures: 1. Relieve pressure, page 13.

2.

Turn main power OFF

.

3.

Allow equipment to cool.

 

Troubleshooting

Problems

Try the recommended solutions in the order given for each problem, to avoid unnecessary repairs. Also, determine that all circuit breakers, switches, and con- trols are properly set and wiring is correct before assum- ing there is a problem.

Power

PROBLEM

CAUSE

SOLUTION

 

 

 

Heat zones do not operate

No power

Connect power cord

 

 

 

 

 

Turn Main Disconnect Switch ON

 

 

 

 

Power cord not connected properly

Check connections

 

 

 

No power when disconnect switch is

Power terminal jumper still at 380V, 3

Place jumpers in correct position; see

turned on; using 230V, 1 phase or

phase position, as shipped from fac-

Operation manual and label inside

230V, 3 phase power

tory

front lower cabinet.

 

 

 

External main supply power circuit

Power terminal jumper was left in

Place jumpers in correct position; see

breaker trips and Reactor disconnect

230V, 1 phase position. When using

Operation manual. Replace main

switch fails when switch is turned on.

230V, 3 phase or 380V, 3 phase

power disconnect switch; see page

 

power

40.

 

 

 

No temperature display lights at

No power

Connect power cord

startup

 

 

 

Turn Main Disconnect Switch ON

 

 

 

 

 

 

Control power fuses blown

Check and replace fuses on long ter-

 

 

minal strip

 

 

 

Pumps and Pressures

PROBLEM

CAUSE

SOLUTION

 

 

 

 

 

 

Pump does not run up and down

Motor control valve closed

Open air motor shutoff valve

 

 

 

 

No air supply

Air supply line not connected

 

 

 

 

 

Open inlet air ball valve

 

 

 

 

Air pressure regulators set at 0 psi

Turn up air pressure regulators

 

 

 

 

Air motor shuttle valve is centered.

Push button on top of air motor shut-

 

 

tle valve.

 

 

 

Pump runs but no fluid pressure

Fluid inlet ball valves closed

Open fluid inlet ball valves

 

 

 