Repair
Remove Air Motor
1.Press in tube fitting ferrules and pull out tubing (65) to disconnect air line.
2.Disconnect DataTrak communication cable, if installed.
3.Place wrench on adapter (315) and a another wrench on lock nut (313). Remove lock nut (313).
315 313
ti17992a
FIG. 1
4. Remove four nuts (310) from tie rods (309).
| 309 |
314 | 301 |
| 310 |
| ti17993a |
FIG. 2 |
|
5.Loosen two screws (314) behind air motor bracket. Carefully lift air motor and tie rods away from the proportioner frame and plate (301).
6.Lay air motor on a clean flat work space. Place a wrench on the tie rod flats (309) and hold one of other tie rods with your hand to keep the air motor (308) in place. Remove the tie rods from the air
motor.
309
308
ti17994a
FIG. 3
7.Use a wrench to hold the piston rod in place and remove the adapter (315) with another wrench. See FIG. 1.
8.See air motor manual for repair instructions.
Install Air Motor
1.Apply medium blue thread lock on adapter (315). Use a wrench to hold the piston rod in place and install the adapter (315) with another wrench.
Torque to
2.Install tie rods (309) in the bottom of the air motor
(308). See FIG. 3.
3.Install tie rods through plate (301). Ensure screws
(314)fit in the bracket slots (311). Install screws
(314). See FIG. 2.
4.Tighten nut (313) to
5.Evenly torque four tie rod nuts (310) in small incre- ments to
24 | 3A1570A |