Repair
34 3A1570A
Replace Circuit Breaker Module
1. Turn main power OFF . Disconnect power
supply. Turn circuit breakers on to test.
2. Relieve pressure, page 13.
3. Using an ohmmeter, check for continuity across cir-
cuit breaker (top to bottom). If no continuity, trip
breaker, reset, and retest. If still no continuity,
replace breaker as follows:
a. Refer to electrical diagrams and table below.
Disconnect wires and remove bad breaker.
NOTE: To reference cables and connectors, see the
electrical diagrams and parts drawings on page 49 and
51.
b. Install new breaker and reconnect wires.
Ref. Size Component
CB1 50 A Hose Secondary (single)
CB2 40 A Hose Primary (double)
CB3 25 A Heater A (double)
CB4 25 A Heater B (double)
FIG. 12
ti17569a
CB1 CB2 CB3 CB4