Parts

Fluid Manifold

4212

4

214

205

 

 

 

 

3

208b

 

 

204

 

208 1

2

 

213

208a 3

 

 

 

 

 

203

 

 

201

206

 

 

 

 

210

209

 

202

 

 

 

 

 

 

ti8459a

 

 

 

207

 

1 Apply sealant and torque to 250 in-lbs (28 N•m).

2Use blue thread lock on valve cartridge threads into manifold.

3Part of item 208.

4Apply lubricant to mating surfaces.

5 Apply pipe sealant to all NPT threads.

Ref.

Part

Description

Qty.

201

24K993

MANIFOLD, recirculation

1

202

108638

FITTING, pipe, tee

2

203

162453

FITTING, (1/4 npsm x 1/4 npt)

2

204

113641

GAUGE, pressure, fluid, SST

2

205

111600

PIN, grooved

2

206

119789

FITTING, elbow, street, 45 deg,

2

207

116704

ADAPTER, 3/8 JIC x 1/4 npt

1

208

239914

VALVE, drain; includes 208a, 208b

2

208a

---

SEAT

2

208b

---

GASKET

2

209

119998

ADAPTER, 5/16 JIC x 1/4 npt

1

210

116702

FITTING, union, 1/4 npt x 3/8 JIC

2

212

187625

HANDLE, valve, drain

2

213189285

LABEL, caution

1

214

224807

BASE, valve

2

Replacement Danger and Warning labels, tags, and cards are available at no cost.

Fluid Inlet Kit, 262695

255

1 254

253

ti18027a

252

251

1Assemble ball valves in orientation shown.

2Apply anaerobic polyacrylate pipe sealant to all NPT connections.

Ref.

Part

Description

Qty.

251

160327

UNION, adapter, 90°; 3/4 npt(m) x

2

 

 

3/4-14 npt(f)

 

252

101078

Y-STRAINER; 20 m screen

2

253

C20487

NIPPLE, 3/4 npt

2

254

109077

VALVE, ball; 3/4 npt (fbe)

2

255

118459

UNION, swivel; 3/4-14 npt(m)x

2

 

 

3/4-14 npt(f)

 

256

180199

ELEMENT, 20 mesh

2

46

3A1570A

Page 46
Image 46
Graco A-25 important safety instructions Fluid Manifold, Fluid Inlet Kit