Repair

11.Push retaining wire clip (307) up. Push retaining pin (306) out.

307

306

301

302

304

303ti17991a

12.Loosen lock nut (302) by hitting firmly with a non-sparking hammer.

13.Unscrew pump out of pump mounting plate (301).

14.See pump manual for repair procedures and replacement parts.

Connect Pump

1.Ensure locknut (302) is screwed on pump with flat side up. Grease pump mounting threads in plate and pump cylinders (303, 304) with lithium grease. Screw pump into pump mounting plate (301) until top of pump thread is above mounting plate 1/2 to 1 1/2 threads above flush.

NOTE: Pump rod connecting links (302) should be posi- tioned so that pins (306) are in line with each other.

2.Align pump rod hole with link hole. Push retaining pin (306) in. Pull retaining wire clip (307) down to cover pin ends.

3.Tighten locknut (302) by hitting firmly with a non-sparking hammer.

4.Install adapter (312) in fluid outlet. Connect A side (21) and B side (23) steel outlet tubes.

5.For Iso A pump only:

a.Install two pipe plugs (324).

b.Reconnect two tubing lines (N) from ISO Pump Lube reservoir. Flush and refill reservoir with TSL 206995.

6.Refill Resin B pump wet cup with TSL 206995.

3A1570A

23

Page 23
Image 23