SECTION 3: CIRCUIT REQUIREMENTS

Voltage & Amperage

Draw

The following list outlines the voltage required to operate the saws, as well as the amperage draw of their motors:

G0444

 

 

110V (prewired)

18

Amps

220V

9

Amps

G0444Z

 

 

110V

24

Amps

220V (prewired)

12

Amps

Circuit Breaker

Use the following guidelines when choosing a cir- cuit breaker (circuit breakers rated any higher are not adequate to protect the circuit):

G0444

 

 

110V (prewired)

20 Amp, 1 Pole

220V

10 Amp, 2 Pole

G0444Z

 

 

110V

25 Amp, 1 Pole

220V (prewired)

15 Amp, 2 Pole

 

 

 

 

 

 

 

 

 

 

 

 

Plug & Receptacle

The following list and figures outline the correct plug and receptacle to use:

G0444

110V (prewired)................................ NEMA 5-15

220V................................................ NEMA 6-15*

*Not Included

Figure 4. NEMA 5-15 plug and receptacle.

Figure 5. NEMA 6-15 plug and receptacle.