SECTION 2: CIRCUIT REQUIREMENTS

110V Operation

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The 112 HP motor on the Model G0458 draws the following amps during normal operation:

Motor Draw

15 Amps

Circuit Requirements

Only connect your machine to a circuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.

Minimum Circuit Requirement

20 Amp

 

 

 

 

Figure 1. Typical plug and receptacle.

-8-

Electrocution or fire could result if this machine is not grounded correctly or if your electrical configu- ration does not comply with local and state codes. Ensure compliance by checking with a qualified electrician!

This machine must have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ground prong from plug to fit into a two-pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.

Extension Cords

We do not recommend using extension cords, but if you find it absolutely necessary:

Use at least a 10 gauge cord that does not exceed 50 feet in length!

The extension cord must also contain a ground wire and plug prong.

A qualified electrician MUST size cords over 50 feet long to prevent motor damage.