-24- Model G0747/G0748 (Mfg. Since 8/12)
Power Feed Test Run
the mill comes with a power feed unit for X-axis
table travel. proper operation of the limit switch
attached to the front middle of the table is criti-
cal for the safe use of this power feed unit. if the
power feed does not operate as expected during
the following steps, disconnect it from power and
contact our tech support at (570) 546-9663 for
assistance.
To test the power feed:
1. Make sure all tools, cables, and other items
are well clear of table movement as you fol-
low these steps.
2. refer to the X-Axis Power Feed section,
beginning on Page 28, to understand how
the power feed, table locks, and limit switch
function.
3. loosen the table locks on the front of the
table.
4. plug the power feed power cord into a
grounded 110V power outlet.
5. Make sure the power feed direction knob is in
the neutral (middle) position, turn the speed
dial counterclockwise to the lowest setting,
then press the on button.
6. turn the direction knob to the left, slowly
turn the speed dial clockwise to increase the
speed, then confirm that the table is moving
to the left.
7. Watch for the table limit stop to hit the limit
switch and turn the power feed OFF, stopping
the table movement.
8. turn the direction knob through the neutral
(middle) position and all the way to the right.
the table should begin moving to the right.
9. Confirm that the table stops moving when
the limit stop presses against the limit switch
plunger.
10. Move the direction knob to the neutral (mid-
dle) position, turn the speed dial to the lowest
setting, and press the oFF button.
Congratulations! the Te st Run of the mill is
complete. Continue to the next page to per-
form the Spindle break-In and Adjustments &
Inspections procedures.