Grizzly G0759 Leadscrew Backlash, Battery Replacement, To adjust the Y-axis leadscrew nut

Models: G0759

1 70
Download 70 pages 36.04 Kb
Page 54
Image 54
Battery Cover
Figure 58. Battery replacement.
2. Remove the old battery, dispose of it accord- ing to state and federal regulations, then replace it with a new one.

Leadscrew Backlash

 

To adjust the Y-axis leadscrew nut:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Locate

the leadscrew nut

underneath the

 

 

 

 

When you turn the handwheels to adjust the posi-

 

 

table through the hole in the base under the

 

 

rubber way cover.

 

 

 

 

 

tion of the table, you will notice slight play (back-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

lash) in the handwheel before the table begins to

2.

Tighten

the

adjustment

screws on

the

move. If this play is greater than 0.008" (measured

 

 

leadscrew

nut in

the

same manner

as

with the dial at the base of each handwheel), then

 

 

 

 

described

for

the

X-axis

leadscrew

adjust-

you will need to adjust the leadscrew nuts.

 

 

 

 

ment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To reach the adjustment screws on the leadscrew

3.

Test the adjustment by

turning one

of

the

nut, you may have to fabricate extensions for

 

 

cross handwheels. The ideal amount of play

your hex wrenches. When adjusting, make adjust-

 

 

 

 

when properly adjusted is 0.003"–0.006".

 

ments in small increments. Attempting to reduce

 

 

 

 

 

 

 

 

 

 

 

 

 

 

backlash to less than 0.003" is impractical and

 

Digital Readout Unit

will add unnecessary wear to both the leadscrews

 

and the leadscrew nuts.

 

To adjust the X-axis leadscrew:

 

Battery Replacement

1. Locate the X-axis leadscrew nut under the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If

the digital

readout unit stops

functioning,

the

middle of the table. The head on the adjust-

battery must be replaced.

 

 

 

 

ment screws face to the right (Figure 57).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To replace the digital readout unit battery:

 

 

 

 

 

 

 

 

 

 

1. Use a wide (#3) standard screwdriver or the

 

Location of

 

 

 

 

 

 

 

edge of a coin to remove the battery cover

 

Adjustment Screws

 

 

 

 

 

 

 

 

 

(Figure 58).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 57. X-axis leadscrew adjusters.

2.Tighten the adjustment screws.

3.Test the adjustment by turning one of the longitudinal handwheels. The ideal amount

of play when properly adjusted is 0.003"– 0.006".

3. Replace the battery cover.

-42-

Model G0704 (Mfg. Since 08/11)

Page 54
Image 54
Grizzly G0759 Leadscrew Backlash, Battery Replacement, To adjust the Y-axis leadscrew nut, To adjust the X-axis leadscrew