GTO 2550 DIP Switches, Important Control Board Settings, DIP Switch #1 - Soft Start/Stop

Models: 2502 2550

1 44
Download 44 pages 56.55 Kb
Page 28
Image 28
CONTROL BOARD SETTINGS

CONTROL BOARD SETTINGS

DIP Switches

NOTE: Leave DIP Switch #3 in the OFF position untill installation is complete, to prevent gate from automatically closing during installation.

Main DIP Switch Settings (MODES)

DIP Switch #1 - Soft Start/Stop

The Soft Start/Stop feature slowly starts the gate as it begins to open and slows the gate as it comes to the closed position. This saves wear and tear on the gate and gate opener system.

DIP Switch #2 - Warning Buzzer

The Warning Buzzer alerts you when the gate opener is beginning to either open or close the gate. It sounds for the first 2 seconds in each direction. It also sounds a warning when the gate obstructs two times in one cycle. Switching this to OFF only disables the open and close warning not the obstruction warning.

DIP Switch #3 - Auto-Close

With the Auto-Close switch in the OFF position the gate will remain open until it receives another signal from an activation device such as a transmitter, keypad, or push button control. With the Auto-Close switch in the ON position the gate opener will automatically close the gate, if the gate is in it's open limit position. The time the gate will remain open is determined using DIP Switches #6 and #7.

DIP Switch #4 - Push/Pull-to-Open

If your gate opens into the property the DIP Switch is set to OFF (factory). If your gate opens out from the property the DIP Switch must be set to the ON position. NOTE: if you have a Push-to- Open gate application you will need a Push-to- Open bracket (see Push-to-Open Instructions on page 30).

DIP Switch #5 - B2/D1 Mode

This DIP Switch must remain in the OFF position unless the gate opener is going to be used by a guard or gate attendant, who can only open the gate when constant pressure is applied to a push button control device.

DIP Switches #6 and #7

The combination of these two switches determines the amount of time the gate will remain open when DIP Switch #3 is set in the ON position.

1

2

3

4

5

6

7

ON

ON

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIP#6

DIP#7

Delay Time for Auto-Close

 

 

 

 

 

 

ON

ON

15 seconds

 

ON

OFF

30 seconds

 

OFF

ON

60 seconds

OFF*

OFF*

120 seconds (factory preset)

 

DIP#5

 

 

 

ON

 

D1 mode, constant pressure to operate gate.

OFF*

 

 

B2 mode, momentary contact to operate gate.

DIP#4

 

 

 

ON

 

Push-to-open operation.

 

OFF*

Pull-to-open operation.

 

 

 

 

 

 

DIP#3

 

 

 

ON

 

Auto-close enabled.

OFF*

Auto-close disabled.

 

 

 

 

 

 

DIP#2

 

 

 

ON*

 

Buzzer warning enabled.

 

OFF

 

Buzzer warning disabled

DIP#1

 

 

 

ON*

 

Soft start enabled.

OFF

 

Soft start disabled.

* Factory preset.