GTO 2502, 2550 Setting Your Personal Transmitter Code, Remove the Transmitter Cover, Step

Models: 2502 2550

1 44
Download 44 pages 56.55 Kb
Page 31
Image 31
Setting Your Personal Transmitter Code

Step 7

Press the transmitter button and allow the gates to return to the fully open position. BOTH YOUR MASTER AND SLAVE GATE’S CLOSED POSITION LIMITS ARE NOW PROGRAMMED.

TESTING YOUR CLOSED LIMIT SETTING:

Press your entry transmitter and allow your gates to close. If CLOSED positions are not correct or need to be changed, you will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-7 again.

CLEARING PROGRAMMED CLOSED LIMIT SETTING:

If you make a mistake and set the limit at the wrong position – press your transmitter to return the gates to their fully opened positions, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the closed limit positions. Follow Steps 1-7 again.

Setting Your Personal Transmitter Code

All GTO transmitters are set to a standard code at the factory and are ready to operate your GTO/PRO Gate Opener®. For your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code. Follow the directions below:

1. Remove the Transmitter Cover

On the back of the transmitter use a small phillips head screw driver to remove the two screws on the sides of the visor clip and separate the front cover from the transmitter. With the front cover removed, the battery and the DIP switches will be exposed. To set a new code, use a small screwdriver to move the switches.

2. Set the transmitter DIP Switches

There are nine (9) transmitter DIP switches; each can be placed in three different positions (+, 0, ). DO NOT set all the switches in the same position, such as all +, all 0, or all . Once the DIP switches have been set to a personal code, replace front cover.

WARNING: No other adjustments should be made inside the transmitter.

LED

+

1

2

 

 

0

 

3

 

 

 

 

 

 

 

4

 

 

 

 

5

6

A23S

 

 

 

 

7

 

 

 

 

8

ALKALINE

 

 

 

9

 

12V

ECE

 

BA

 

 

 

ER

 

 

TT

 

 

 

 

 

Y

 

+1 2 3 4 5 6 7 8 9 0 1. Remove the Transmitter Cover2. Set the transmitter DIP Switches3. “Teach” the New Code to Control Board MemoryC.Release LEARN TRANSMITTER button.Manual backgroundManual backgroundManual backgroundManual backgroundManual background

ECE

3. “Teach” the New Code to Control Board Memory

A.Press and hold transmitter button.

B.Press and hold the LEARN TRANSMITTER button on the control board for 5 seconds.

C.Release LEARN TRANSMITTER button.

D.Release transmitter button. The new code is stored in control board memory.

COM

CYCLE CLOSE

SAFETY

EXIT/

OPEN

SHADOW

LOOP

CLOSE

EDGE

OPEN

EDGE

GRN BLK RED RECEIVER

Manual backgroundManual backgroundManual background IN Manual background

M

Manual backgroundManual background STALLFORCEManual background XAMManual background

 

 

MODES

LEARN TRANSMITTER

1 2 3 4

1 2 3 4 ON

 

5

5

 

6

6

 

7

7

 

OFF

ON

 

 

 

DUAL MODES

 

 

1

1 ON

SET LIMIT

2

2

3

3

 

 

4

4

 

 

OFF

ON

 

 

 

 

Learn Transmitter Button

27

Page 31
Image 31
GTO 2502 Setting Your Personal Transmitter Code, Remove the Transmitter Cover, Set the transmitter DIP Switches, Step