Navigating the
CAMERA settings
Please note that this particular list is only an illustration.
Camera choice displayed will vary according to adapter fitted.
MAINMENU>SETTINGS>Camera
Exposure Cable 503
Hasselblad 503CW plus Winder CW with Exposure cable 503 in place showing connection from Winder to adapter.
The camera choices that appear on the menu are automatically restricted to the adapter you have fitted. So, if you have have fitted an adapter specifically intended for Hasselblad models, then only Hasselblad models will appear. The following is a description of settings and action needed when working with the various Hasselblad models.
The exposure time set on a CF digital back sets the maximum length of exposure. The default setting is 1/8 sec and this is the setting that can be kept for all exposures from 1/8 sec. However, this setting should be changed in accordance with the time required if it exceeds 1/8 sec. Times of up to 32 seconds can be set.
If you prefer, you can connect the ‘Flash sync input cable’ between the lens PC socket and a CF digital back which allows you to retain the default setting of 1/8 second while still being able to use exposure times longer than 1/8 second. This method also allows the use of the B setting.
Model setting variations
Look in the list below for the camera model you are using and make the appropriate set- tings change. Don’t forget to change the setting if you change camera model!
Please note that certain connection cables /cords are only included as accessories to certain adapters. Please see adapter manuals for further information.
Winder CW
For use with 503 CW models:
•Make a Winder CW setting.
•If you want to control the camera from FlexColor, connect the Exposure cable 503 between a CF digital back and the Winder CW.
•Do not use the winder at rapid sequence setting.
ELD
For use with ELD models:
•Make an ELD setting.
•A B setting exposure can be made by choosing the “Bulb” in the “Exposure Time” setting. The maximum exposure time remains at 32 seconds however.