B. Clearances to Combustibles (UL and ULC)

R

3100 Wood Stove Series (ACC)

B. Clearances to Combustibles (UL and ULC)

BACKWALL / SIDEWALL

A

B

 

C

 

D

CORNER INSTALLATION

E

F

E

F

NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction

90° OFF TOP

H*

UP & OUT CEILING

G

CLEARANCE

 

STOVE TO CEILING

 

CLEARANCE

 

ALCOVE SIDE VIEW

G

A

 

 

B

ALCOVE TOP VIEW

C

D

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)

NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.

 

A

B

C

D

E

F

G

H

INSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove Top

 

 

 

SINGLE WALL PIPE

 

 

 

 

 

 

 

 

Flat Top Model

15.25 (387) 11.75 (298)

25.5 (648)

16 (406)

8 (203)

17 (432)

48 (1220)

12 (305)

Step-Top Model

12 (305)

8.5 (216)

22 (559)

12.5 (318)

5.5 (140

14.5 (368)

48 (1220)

12 (305)

DOUBLE WALL PIPE

 

 

 

 

 

 

 

 

Flat Top Model

10.5 (267)

6.5 (165)

22 (559)

13 (330)

6.5 (165)

15.5 (394)

48 (1220)

9 (229)

Step-Top Model

10 (228)

6 (152)

20.5 (521)

11 (279)

4 (102)

13 (330)

48 (1220)

9 (229)

INSTALLATION: 90° Elbow Off Top of Stove Through Backwall

 

 

 

 

 

SINGLE WALL PIPE

 

 

 

 

 

 

 

 

Flat Top Model

12 (305)

8.5 (216)

22 (559)

13 (330)

8 (203)

17 (432)

48 (1220)

12 (305)

Step-Top Model

10 (254)

6 (152)

20.5 (521)

11 (279)

5.5 (140)

14.5 (368)

48 (1220)

12 (305)

DOUBLE WALL PIPE

 

 

 

 

 

 

 

 

Flat Top Model

8 (203)

4.5 (114)

17.5 (445)

8.5 (216)

6.5 (165)

15.5 (394)

48 (1220)

9 (229)

Step-Top Model

10 (254)

6 (152)

20.5 (521)

11 (279)

4 (102)

13 (330)

48 (1220)

9 (229)

INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove shall be no more than 48 inches (1220mm) with a minimum height of 48 inches (1220mm) to top of unit, and the referenced clearances.

*In Canada must comply with CAN/ULC-S269 M87 for the 650oC Factory-built chimney.

DOUBLE WALL PIPE

 

 

 

 

 

 

 

 

Flat Top Model

11.75 (298)

8.25 (210)

23.5 (597)

14.5 (368)

N/A

N/A

48 (1220)

*

Step-Top Model

10 (254)

6.5 (152)

20.5 (521)

11 (279)

N/A

N/A

48 (1220)

*

* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters) WARNING

Fire Risk.

Comply with all minimum clearances to combustibles as specified.

Failure to comply may cause house fire.

NOTE: Service Space

In order to replace the tube channel assembly a clearance of 19 inches (483mm) is required on the right side of stove in order to remove the tubes with the stove in place.

If space is not available, the stove will have to be discon- nected from the chimney to proceed with the tube replace- ment.

September 1, 2008

7033-277F

Page 11

Page 11