C.Blower (Optional)

R

3100 Wood Stove Series (ACC)

C.Blower (Optional)

1.Remove the 3 bolts (1/4”-20 Phillips head) on the outer skin at the bottom rear of appliance.

2.Align holes in mounting flange of blower with bolt holes in appliance. Blower should be positioned at bottom of rear outer skin as shown in Figure 15.1.

3.Re-insert and tighten bolts, securing blower onto outer wall of appliance.

4.Place the bracket containing the snap disc and magnet under the bottom left rear corner as shown in Figure 15.1.

See page 30 for detailed operating instructions for the blower and snap disc.

 Shock Risk. Caution

Snap Disc Bracket with Magnet Shock Risk.

Do NOT remove grounding prong from plug.

Plug directly into properly grounded 3 prong receptacle.

Route cord away from appliance.

Do NOT route cord under or in front of appliance.

Snap Disc Bracket with Magnet

Secure wires with wire tie

 

MANUAL: Over-rides the

MANUAL

Snap Disc

 

FAN

AUTO

 

AUTO: Fan will turn ON/OFF

LOW

Automatically by the Snap Disc

HIGH OFF

Controls the Fan Speed

Figure 15.1