Hearth and Home Technologies EXCLAIM-36 Framing & Clearances, A. Select Fireplace Location, Model

Models: EXCLAIM-36

1 56
Download 56 pages 3.78 Kb
Page 18
Image 18
6 Framing & Clearances

6 Framing & Clearances

A. Select Fireplace Location

 

 

 

 

 

Note: Exclaim-36 - 1 in. (25 mm)

 

F

 

 

 

Exclaim-42 - 1 1/2 in. (38

 

 

 

G

mm) minimum distance

 

 

 

 

E

 

 

 

 

from sides & back of

 

 

 

 

fireplace to combustible

 

 

 

 

 

 

 

 

 

 

materials.

 

 

 

A

 

BOTH - 1/2 in. (13 mm)

 

 

 

B

H

minimum at nailing flanges.

 

 

Across a

In an exterior

Note: In addition to these

 

 

chase or projecting

 

 

 

corner

 

framing dimensions, also

 

A

into a garage

 

 

 

 

reference the following

 

 

 

 

 

 

 

 

 

sections:

D

C

 

 

 

Clearances (Section

 

 

 

 

6.B.)

 

 

G

 

 

Mantel Projections

 

 

 

 

 

 

(Section 11.E.)

 

 

 

 

H

Fireplace Dimensions

 

 

 

Along a wall

 

(Section 13.A.)

 

 

 

B

 

5/8 in. (16 mm)

 

B A

 

A

 

all configurations

 

 

 

 

 

 

48 in.

 

 

 

G

 

 

(1219 mm)

 

 

 

 

 

min.

 

 

 

 

 

 

H

 

As a room

 

 

 

 

 

 

divider

 

 

 

 

Model

 

A

B

C

D

E

F

G

H

EXCLAIM-36

inches

45 1/2

53 1/2

85

42 1/2

19 3/8

60 1/8

28

 

mm

1156

1359

2159

1080

492

1527

711

24 in. (610 mm)

 

 

 

 

 

 

 

 

 

 

Minimum from FP opening to

 

inches

52

59 1/2

92 3/4

46 3/8

21 1/2

65 5/8

28 1/2

EXCLAIM-42

any perpendicular wall.

mm

1308

1511

2356

1178

546

1667

724

 

 

 

Figure 6.1 Fireplace Locations (Framing dimensions shown)

18

Heat & Glo • EXCLAIM-36, EXCLAIM-424013-251 Rev C • 11/08

Page 18
Image 18
Hearth and Home Technologies EXCLAIM-36 owner manual Framing & Clearances, A. Select Fireplace Location, Model