A. Chimney Requirements

Measure vertical distances from the base of the fireplace as shown in Figure 8.2.

 

ft

m

• Minimum overall straight height

18

5.49

• Minimum height with offset/return

18.5

5.64

• Maximum height

90

27.43

• Maximum chimney length between an

20

6.10

offset and return

 

 

• Maximum distance between chimney

35

10.67

stabilizers`

 

 

• Double offset/return minimum height

24

7.32

• Maximum unsupported chimney length

6

1.83

between the offset and return

 

 

• Maximum unsupported chimney height

35

10.67

above the fireplace

 

 

• Maximum unsupported chimney above

6

1.83

roof

 

 

WARNING! Risk of Fire! You must maintain 2 in. (51

mm)air space clearance to insulation and other combus- tible materials around the chimney system. Failure to do so may cause overheating and fire.

Determine the chimney components needed to complete your particular installation:

Measure the total vertical height of the fireplace installation from the base of the fireplace assembly to the approximate location of the bottom of the termination cap.

Subtract the effective height of the fireplace assembly (see Figure 8.2) from the total vertical height to determine the overall height of the chimney installation.

Create a schematic for your application similar to Figure 8.2 showing components required (referring to Table 8.1). Figure 8.1 identifies those components and where used.

Install a ceiling firestop whenever the chimney penetrates a floor/ceiling.

NOTICE: A maximum of two pairs of offsets and returns may be used.

CAUTION! Risk of Fire and/or Asphyxiation! DO NOT connect this fireplace to a chimney flue servicing another appliance. DO NOT connect to any air distribu- tion duct or system. These actions could cause over- heating/fire in the chimney flue, or release of exhaust fumes into the living areas.

Î Table 8.1

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

US

 

Canada ONLY

 

 

Chimney Stabilizer

 

 

 

SL11

 

SL4

4-3/4

121

Ceiling Firestops

 

 

 

FS538

 

FS538

0

0

 

 

 

 

 

FS540

 

FS540

0

0

Offsets/Returns

 

 

 

SL1130

 

SL430

14-1/2

368

Roof Flashing

 

 

 

RF570

 

RF570

0

0

RF571

 

RF571

0

0

Chimney Sections*

 

 

 

SL1106

 

SL406

4-3/4

121

SL1112

 

SL412

10-3/4

273

 

 

 

 

 

SL1118

 

SL418

16-3/4

425

SL1136

 

SL436

34-3/4

883

 

 

 

 

 

SL1148

 

SL448

46-3/4

1187

 

 

 

 

 

n/a

 

SLA10

16-3/4

425

* Dimensions reflect effective height.

6 ft (1.8 m) max. unsupported run

20 ft (6 m) max. pipe between an offset & return

Ceiling Firestop

11-10 in./279-254mm adaptor required in Canada

55-1/2 in.

(1410 mm)

Effective Height

(bottom of fireplace

to top of starter collar)

6 ft (1.8 m) max. unsupported chimney above roof

35 ft (10.7 m) max. straight unsupported chimney height

18.5ft (5.6 m) min. height single offset-return

24 ft. (7.3 m) min. height

double offset-return

90 ft (27.4 m) max. height

Figure 8.2 Chimney Requirements