Hearth and Home Technologies EXCLAIM-36 C. Sidewalls/Surrounds, D. Frame the Fireplace, 4 in

Models: EXCLAIM-36

1 56
Download 56 pages 3.78 Kb
Page 20
Image 20
C. Sidewalls/Surrounds

C. Sidewalls/Surrounds

Adjacent combustible sidewalls must be located a minimum 24 in. (610 mm) from the fireplace opening.

Combustible and noncombustible mantel legs, surrounds and stub walls may be constructed within the gridded area, Figure 6.3.

Note: Grid depicts 1-in scale.

FLUSH

BRICK

4 in.

[102 mm]

FRONT

FRONT

A

28 5/8 in.

[727 mm]

50°

angle

 

24in.

[610 mm]

B

39°

angle

 

24in.

[610 mm]

19 3/4 in.

[502 mm]

Model

 

A

B

EXCLAIM-36

inches

36

45

mm

914

1130

 

 

 

 

 

EXCLAIM-42

inches

42

50 1/2

mm

1067

1283

 

Figure 6.3 Mantel Leg or Wall Projections (Acceptable on both sides of opening)

D. Frame the Fireplace

Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).

Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.

Framing across the top of fireplace must be above top standoffs.

2 in. (51 mm) min. air space clearance from chimney.

Note: Framing must be extended straight up, all the way to the ceiling.

 

Header MUST NOT be notched!

 

 

 

 

 

 

 

D = extra space needed for outside air connection.

 

 

 

 

C

If outside air duct has no bend, this dimension may be

 

 

 

reduced as long as minimum clearances are met.

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

D

 

A

Model

A

 

B*

C**

B

 

 

(4” duct)

(6” duct)

 

 

EXCLAIM-36

in.

45 1/2

 

28

50

8

12

 

 

 

 

 

 

 

 

 

 

 

mm

1156

 

711

1270

203

305

 

 

 

 

 

 

EXCLAIM-42

in.

51 1/2

 

28 1/2

50

8

12

 

 

 

 

 

 

 

 

 

 

 

mm

1308

 

724

1270

203

305

 

 

 

 

*If interior of chase will be drywalled, add the thickness to this measurement.

**Adjust header height for a raised floor under fireplace.

Figure 6.4 Framing the Fireplace

20