B. Install Fireplace & Chimney

Install as per Sections 7 and 8.

C. Install Chase Top

• You MUST use a chase top in a chase installation. Chase

tops are available from your Heat & Glo dealer or may

be field constructed.

• Include a turndown and drip edge to prevent water from

seeping into the chase.

• Include a 2 in. (51 mm) soldered, caulked or spun collar

around pipe opening to keep water out.

• Provide a 1/8 in. (3 mm) gap around the flue pipe.

• Slope the chase top downward away from the

opening.

CAUTION! DO NOT caulk the pipe to the chase top

collar.

• Caulk all seams to prevent leaks.

• Refer to Figure 9.4.

Slope Downward (1/4 in. per foot minimum)

2 in. (51 mm) Collar on Chase Top

Turn-down

Drip Edge

Chase

.018 (26 ga) min. Galvanized Chase Top

Figure 9.3 Chase Top Construction

Heat & Glo • EXCLAIM-36, EXCLAIM-424013-251 Rev C • 11/08

35

Page 35
Image 35