F. Sidewalls/Surrounds

Adjacent combustible sidewalls must be located a minimum of 24 in. (610 mm) from the fireplace opening.

Combustible or non-combustible mantel legs, surrounds and stub walls may be constructed per Figure 11.12.

4 in. [102 mm]

19 3/4 in.

[502 mm]

 

BRICK FRONT

39°

angle

 

1-in scale.

 

 

 

 

 

depicts

A

B

Note: Grid

angle

 

FLUSH FRONT

50°

 

 

 

28 5/8 in.

[727 mm]

 

Figure 11.12 Mantel Leg or Wall Projections (acceptable on both sides of opening)

24 in. [610 mm]

24 in. [610 mm]

B

45

1130

50 1/2

1283

 

 

 

 

 

A

36

914

42

1067

 

 

 

 

 

 

inches

mm

inches

mm

 

 

 

 

 

Model

EXCLAIM-36

EXCLAIM-42

Heat & Glo • EXCLAIM-36, EXCLAIM-424013-251 Rev C • 11/08