Hearth and Home Technologies EXCLAIM-36 E. Combustible Mantel, 12 in./305 mm, EXCLAIM-42

Models: EXCLAIM-36

1 56
Download 56 pages 3.78 Kb
Page 44
Image 44
E. Combustible Mantel

E. Combustible Mantel

See Figure 11.11.

A combustible mantel may be positioned no lower than 12 in./305 mm (EXCLAIM-36) OR 20 in./508 mm (EXCLAIM-42) above the top of the fireplace opening.

A combustible mantel may have a maximum depth of 12 in. (305 mm).

Combustible trim and materials cannot be placed within 6 in. (152 mm) of the fireplace opening (top or sides).

Combustible materials projecting more than 1-1/2 in. (38 mm) shall not be placed within 12 in. (305 mm) from the top of the fireplace opening.

Combustible trim must not cover the metal surfaces of the fireplace.

Mantel clearance is in accordance with Section 7-3.3.3of ANSI/NFPA211.

12 in.

(305 mm)

*

55-1/2 in.

 

 

(1410 mm)

Top of

Effective

Height

Fireplace

 

Opening

 

*

EXCLAIM-36

12 in./305 mm

 

EXCLAIM-42

20 in./504 mm

Figure 11.11 Clearances to Mantels or other Combustibles above Fireplace

44

Heat & Glo • EXCLAIM-36, EXCLAIM-424013-251 Rev C • 11/08

Page 44
Image 44
Hearth and Home Technologies EXCLAIM-36 owner manual E. Combustible Mantel, 12 in./305 mm, EXCLAIM-42, 20 in./504 mm