D. Intellifire Ignition System Wiring

This appliance requires a 110 VAC supply to the appliance junction box for operation. When using the transformer, the junction box must have uninterrupted 120V. A wiring diagram is shown in Figure 7.3.

This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.

This appliance is supplied with a battery pack and a 3 volt AC transformer, which requires the installation of the supplied junction box. It is highly recommended that the junction box be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not included).

NOTE: Batteries cannot be placed in the battery pack while using the 3 volt AC transformer. The transformer must be unplugged if the battery pack is used or battery life will be reduced.

CAUTION

Battery polarity must be correct or module damage will occur.

Optional Accessories Requirements

Wiring for optional accessories should be done now to avoid reconstruction.

PLUG-IN

IGNITION MODULE

3 VAC

3V TRANSFORMER

 

ON/OFF

WALL

SWITCH

FLAME SPARKER/

SENSOR

IGNITION MODULE (3V)

VALVE

LOW VOLTAGE

 

SEE NOTE 1

 

GROUND REMOTE

NEUTRAL

CONTROL HOT

 

WHITE WIRE

 

CAN BE

 

PLUGGED

 

INTO ANY

BLACK WIRE CAN BE

OF #1-#5

PLUGGED INTO ANY OF

LOCATIONS

#1 - #5 LOCATIONS

ON THE

ON THE HOT SIDE

NEUTRAL SIDE TRANSFORMER

 

3 VAC

 

PLUG IN

I

S

WHT

ORG

GROUND TO

FIREPLACE

CHASSIS

BRN

BRN

*

 

ORG

PIGGYBACK

ON/OFF SWITCH

VALVE

INTERMITTENT

PILOT

IGNITOR

GRN

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts.

Uninterrupted 120 VAC is required at junction box unless equipped with battery back-up.

Figure 7.3 Intellifire Pilot Ignition (IPI) Wiring Diagram

Heat & Glo LifeStyle Collection • Twilight-II-B2108-900 Rev. G • 8/07

19