5 Framing and Clearances

A. Selecting Appliance Location

When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.

A

J

A

L

F

C

K

D

B

 

N

 

E

 

F

C

A

 

G

I

J

G

M

Models

A

B

C

D

E

F

G

H

I

J

K

L

M

N

Min.

Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QV32B-A

in.

42

37

59-1/2

See Section

1

1/2 Min.

44

62-1/4

16-1/4

48-1/2

68-3/4

15-1/16

7-1/2

7-1/8

mm

1066

940

1511

25

13

1117

1734

413

1231

1746

383

191

181

 

 

 

 

 

D for Alcove

 

 

 

 

 

 

 

 

 

 

 

in.

45-1/2

42

64-3/8

1

1/2

45-1/2

64-3/8

16-1/4

48-1/2

68-3/4

16-5/8

7-1/2

9

QV36B-A

Installation

mm

1155

1067

1635

25

13

1321

1861

413

1231

1746

422

191

229

 

Figure 5.1 Appliance Locations

Quadra-FireQV32B-A, QV36B-A2014-900 Rev. U • 1/12

17

Page 17
Image 17
Hearth and Home Technologies QV36B-A, QV32B-A owner manual Framing and Clearances, Selecting Appliance Location