Rear Vent - Horizontal Termination No Elbows

Note: Use DVP Series components only.

Figure 7.12

H1 = 24 in. (711 mm) Maximum

H1

Note: Use DVP Series components only.

Rear Vent - Horizontal Termination

Venting with 2 elbows

H1 MAX.

 

V1 MIN.

H2 MAX.

H1 + H2 MAX.

1-1/2 ft.

457 mm

Back to back elbows

1 ft.

305 mm

2-1/2 ft.

762 mm

 

 

 

 

 

 

 

 

 

3 ft.

914 mm

1 ft.

 

305 mm

3 ft.

914 mm

6 ft.

1.8 m

 

 

 

 

 

 

 

 

 

5 ft.

1.5 m

3 ft.

 

914 mm

5 ft.

1.5 m

10 ft.

3.0 m

 

 

 

 

 

 

 

 

 

7 ft.

2.1 m

5 ft.

 

1.5 m

7 ft.

2.1 m

14 ft.

4.3 m

 

 

 

 

 

 

 

 

 

H1 MAX. = 7 ft. (2.1 m)

H1 + H2 MAX. = 14 ft. (4.3 m)

V1 + H1 + H2 MAX. = 40 ft. (12.2 m)