Note: Use DVP Series components only.

INSTALLED

HORIZONTALLY

Rear Vent - Horizontal Termination

Venting with 3 elbows

H1 MAX.

 

V1 MIN.

H1 + H2 MAX.

H1 + H2+ H3 MAX.

1-1/2 ft.

457 mm

Back to back elbows

1 ft.

305 mm

2-1/2 ft.

762 mm

 

 

 

 

 

 

 

 

 

3-1/2 ft.

1.1 m

1 ft.

 

305 mm

2 ft.

610 mm

5-1/2 ft.

1.7 m

 

 

 

 

 

 

 

 

 

5-1/2 ft.

1.7 m

2 ft.

 

610 mm

4 ft.

1.2 m

9-1/2 ft.

2.9 m

 

 

 

 

 

 

 

 

 

7-1/2 ft.

2.3 m

3 ft.

 

914 mm

6 ft.

1.8 m

13-1/2 ft.

4.1 m

 

 

 

 

 

 

 

 

 

H1 MAX. = 7-1/2 ft. (2.3 m)

H1 + H2+ H3 MAX. = 13-1/2 ft. (4.1 m)

V1 + H1 + H2+ H3 MAX. = 40 ft. (12.2 m)

H3H2

V1

Figure 7.14

H1

Note: Use DVP Series components only.

Rear Vent - Vertical Termination

Venting with 1 elbow

 

V1 MIN.

H1 MAX.

1 ft.

 

305 mm

3-1/2 ft.

1.1 m

 

 

 

 

 

2 ft.

 

610 mm

5-1/2 ft.

1.7 m

3 ft.

 

914 mm

7-1/2 ft.

2.3 m

 

 

 

 

 

H1 MAX. = 7-1/2 ft. (2.3 m)

V1 + H1 MAX. = 40 ft. (12.2 m)

V1

H1

Figure 7.15

32

Quadra-FireQV32B-A, QV36B-A2014-900 Rev. U • 1/12

Page 32
Image 32
Hearth and Home Technologies QV32B-A Rear Vent Horizontal Termination Venting with 3 elbows, H1 + H2 MAX H1 + H2+ H3 MAX