Note: Use DVP Series components only.
INSTALLED
HORIZONTALLY
Rear Vent - Horizontal Termination
Venting with 3 elbows
H1 MAX. |
| V1 MIN. | H1 + H2 MAX. | H1 + H2+ H3 MAX. | ||||
457 mm | Back to back elbows | 1 ft. | 305 mm | 762 mm | ||||
|
|
|
|
|
|
|
|
|
1.1 m | 1 ft. |
| 305 mm | 2 ft. | 610 mm | 1.7 m | ||
|
|
|
|
|
|
|
|
|
1.7 m | 2 ft. |
| 610 mm | 4 ft. | 1.2 m | 2.9 m | ||
|
|
|
|
|
|
|
|
|
2.3 m | 3 ft. |
| 914 mm | 6 ft. | 1.8 m | 4.1 m | ||
|
|
|
|
|
|
|
|
|
H1 MAX. =
H1 + H2+ H3 MAX. =
V1 + H1 + H2+ H3 MAX. = 40 ft. (12.2 m)
H3H2
V1
Figure 7.14
H1
Note: Use DVP Series components only.
Rear Vent - Vertical Termination
Venting with 1 elbow
| V1 MIN. | H1 MAX. | ||
1 ft. |
| 305 mm | 1.1 m | |
|
|
|
|
|
2 ft. |
| 610 mm | 1.7 m | |
3 ft. |
| 914 mm | 2.3 m | |
|
|
|
|
|
H1 MAX. =
V1 + H1 MAX. = 40 ft. (12.2 m)
V1
H1
Figure 7.15
32 |