Top Vent - Horizontal Termination

Venting with 3 elbows (NG)

V1 Minimum

H1 + H2 Maximum

90 Elbow

0 ft.

0 mm

 

 

 

 

1/2 ft.

152 mm

1 ft.

305 mm

 

 

 

 

1-1/2 ft.

457 mm

2 ft.

610 mm

 

 

 

 

2-1/2 ft.

762 mm

4 ft.

1.2 m

 

 

 

 

3-1/2 ft.

1.1 m

6 ft.

1.8 m

 

 

 

 

H1 + H2 MAX. =14 ft. (4.3 m)

V1+ V2 + H1 + H2 MAX. = 40 ft. (12.2 m)

Note: Use SLP Series components only.

Top Vent - Horizontal Termination Venting with 3 elbows (Propane)

V1 Minimum

H1 + H2 Maximum

90 Elbow

Not Allowed

 

 

 

 

1/2 ft.

152 mm

0 ft.

0 mm

 

 

 

 

1-1/2 ft.

457 mm

2 ft.

610 mm

 

 

 

 

2-1/2 ft.

762 mm

4 ft.

1.2 m

 

 

 

 

3-1/2 ft.

1.1 m

6 ft.

1.8 m

 

 

 

 

H1 + H2 MAX. =14 ft. (4.3 m)

V1+ V2 + H1 + H2 MAX. = 40 ft. (12.2 m)

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.3).

H2

V2

H1

V1

Figure 7.6

26

Quadra-FireQV32B-A, QV36B-A2014-900 Rev. U • 1/12