Step 3

Installing the

Flue System

A. Flue System Approvals

These models have flue starting collars on both the top and the back of the unit. Depending upon the installation, decide which ONE set of starting collars will be used to attached the flue system. The starting collar sealing cap must remain on the starting collar NOT used.

These models use DVP-series direct flue components when using the TOP and REAR flue collars.

Approved flue system components are labeled for identification.

NO OTHER FLUEING SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are included with each flue termination kit and should be used in conjunction with this Installers Guide. Figure 4 shows flue system components and terminations.

Identifying Flue Components

The flue systems installed on this gas fireplace may include one, two, or three 90° elbow assemblies. The relationships of vertical rise to horizontal run in flue configurations using 90° elbows MUST BE strictly adhered to. The rise to run relationships are shown in the flueing drawings and tables on the next several pages.

Note: Two 45° elbows may be used in place of one 90° elbow. You MUST always maintain the MAXIMUM and MINIMUM rise- to-run ratios in the flue system when using 45° elbows.

 

VERTICAL

STORM COLLAR

 

TERMINATION

 

 

 

HORIZONTAL

 

 

ROOF FLASHING

 

 

 

 

 

TERMINATION

 

 

 

 

 

 

 

HORIZONTAL PIPE

 

 

 

 

SUPPORT

 

 

 

 

PIPE LENGTH

 

WALL FIRESTOP

 

 

 

 

 

90 DEGREE

 

 

 

 

ELBOW

CEILING

 

 

 

 

WALL BRACKET

 

 

 

FIRESTOP

 

 

 

 

 

FLUE SYSTEM TERMINATION KITS

 

 

 

DVP-SERIES

 

 

 

DVP-TVHW

DVP-TRAP

 

 

 

Figure 5. Flue Components and Terminations

 

 