Symptom

Possible Cause

Corrective Action

 

 

 

5. The pilot and

a. No LP in the tank

Check the LP (propane) tank. Refill the

main burner

 

fuel tank.

extinguish while

 

 

b. Inner flue pipe leaking

Check for gas leaks.

in operation.

 

exhaust gases back into

 

 

the system

 

 

 

 

 

c. Horizontal flue improperly

The horizontal flue cap should slope down

 

pitched

only enough to prevent any water from

 

 

entering the unit. The maximum downward

 

 

slope is 0.6 cm.

 

 

 

 

d. Glass too loose and

Tighten the corner.

 

air tight packet leaks in

 

 

corners after usage

 

 

 

 

 

e. Bad thermopile or

Replace if necessary.

 

thermocouple

 

 

 

 

 

f. Improper flue cap

Check for proper installation and freedom

 

installation

from debris or blockage.

 

 

 

6. Glass soots.

a. Flame impingement

Adjust the log set so that the flame does

 

 

not excessively impinge on it.

 

 

 

 

b. Improper venturi setting

Adjust the air shutter at the base of the

 

 

burner.

 

 

 

 

c. Debris around venturi

Inspect the opening at the base of the

 

 

burner. NO MATERIAL SHOULD BE

 

 

PLACED IN THIS OPENING.

 

 

 

7. Flame burns

a. Insufficient oxygen being

Ensure that the flue cap is installed properly

blue and lifts off

supplied

and free of debris. Ensure that the flue

burner.

 

system joints are tight and have no leaks.

 

 

Ensure that no debris has been placed in

 

 

the area at the base of, or in the area of,

 

 

the air holes in the center of the base pan

 

 

beneath the burner.

 

 

Ensure that the glass is tightened properly

 

 

on the unit, particularly on top corners.

 

 

 

Heat & Glo • 6000TRS-CE2049-900 Rev. Q • 2/11

43

Page 43
Image 43
Heat & Glo LifeStyle 6000TRS-CE manual Placed in this Opening