The heat shield sections will overlap to match the wall thickness (depth). The small leg in the shield rests on top of the flue to properly space it from the pipe section (see Figure 22).

Interior

Rear Vent

Wall Shield

Heat Shield

 

3.8 cm min.

 

overlap

Outer Flue

Inner Flue

3.8 cm min.

Overlap

INTERIOREXTERIOR

Figure 22. Venting through the Wall

The termination kit should pass through the wall fire- stops from the exterior of the building.

Adjust the termination cap to its final exterior position on the building and interlock the flue sections.

WARNING: THE TERMINATION CAP MUST

!BE POSITIONED SO THAT THE ARROW IS POINTING UP.

Use a high-temperature sealant gasket to seal between the pipe and exterior firestop.

Heat & Glo • 6000TRS-CE2049-900 Rev. Q • 2/11