V

H

Figure 9. Flue with One 90° Elbow

FLUE WITH ONE (1) 90o ELBOW

V

H

MIN. 30.5 cm

MAX. 61.0 cm

MIN. 61.0 cm

MAX. 1.22 m

MIN. 91.4 cm

MAX. 1.86 m

MIN. 1.22 m

MAX. 2.48 m

MAX. 7.3 m

MAX. 2.48 m

FLUE WITH ONE (1) 90o ELBOW

V

H

MIN. 30.5 cm

MAX. 1.22 m

MIN. 61.0 cm

MAX. 2.4 m

MIN. 91.4 cm

MAX. 3.7 m

MIN. 1.22 m

MAX. 4.9 m

V + H = MAX 7.3 m

H = MAX. 2.4 m

 

 

 

H

V

NOTE: For corner installations: A 15.2 cm MINIMUM length of straight pipe must be first attached to the fireplace before 90o elbow. This will allow the flue pipe to clear the top standoffs.

NOTE: If a 90º elbow is first attached to the unit, the maximum horizontal run is 3 feet (91.4 cm).

Figure 10. Flue with One 90° Elbow

Heat & Glo • 6000TRS-CE2049-900 Rev. Q • 2/11

15

Page 15
Image 15
Heat & Glo LifeStyle 6000TRS-CE manual Flue with ONE 1 90o Elbow