Heat & Glo LifeStyle SUPREME-P-I30AU B. Mantel and Wall Projections, Side View, Top View

Models: SUPREME-P-I30AU SUPREME-N-I30AU

1 60
Download 60 pages 51.13 Kb
Page 20
Image 20

1-1/2 in.

(38 mm)

BD

CD

SURROUND

APPLIANCE

SIDE VIEW

AD

SURROUND

APPLIANCE

TOP VIEW

MINIMUM FIREPLACE SIZE (1-1/2 IN. (38 mm) Surround Depth)

 

Location

 

SUPREME-I30AU

 

Inches

 

Millimeters

 

 

 

AD

Alternate Unit Width

29-1/16

 

738

BD

Alternate Unit Depth

13-7/8

 

352

CD

Alternate Unit Height

19-1/16

 

484

*Note: If exhaust collar on insert and fireplace damper do not line up, add 4 in. (102 mm) to minimum fireplace height for bends in vent pipe.

Figure 5.3 Fireplace Opening - Deep Surround

B. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).

Clearance to combustible material under the insert is 1/4 in. (6 mm). Clearance from top of fireplace opening for combustibles extending 12 in. (305 mm) max. is 12 in (305 mm)

Use leveling legs to raise insert minimum 1/4 in. (6 mm) above combustible material or outer wrap of factory built firebox.

Combustible facings must not extend behind the insert surround. For non-combustible material specifications refer to Section 1.E.

NON-COMBUSTIBLE FACING

 

12 in.

 

(305 mm)

 

MAX.

 

MINIMUM CLEARANCE

TO COMBUSTIBLE

12 in.

MANTEL OR

(305 mm)

PROJECTION

MIN.

Figure 5.4 Mantel Clearances or Other Combustibles Above Appliances

20

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

Page 20
Image 20
Heat & Glo LifeStyle SUPREME-P-I30AU, SUPREME-N-I30AU owner manual B. Mantel and Wall Projections, Side View, Top View