F. Vent Kits Components

Direct Vent Flex Liner Accessory Kits (see Figure 8.9).

LINK-DV30B: Masonry 3 in. (76 mm) flex liner kit. Expands

to 30 ft. (9 m). Includes: two liners, termination cap, flashing, and link adapter.

Flash-Damp: Zero clearance damper flashing kit for use with the LINK-DV30B liner kit.

LINK-ZC-ADP: Zero clearance chimney adapter

DV-46DVA-GK: Adapter kit. It is permissible to use DV- 46DVA-GK to connect collinear flex vent to SL-D vent pipe to extend the run.

FLEX3-30: One 3 in. (76 mm) flexible liner expands to 30 ft . (9 m).

FLEX-CNCT: Connector kit - 3 in. (76 mm) liner to 3 in. (76 mm) liner, one connector per kit.

FLEX3-30

LINK-DV30B

FLASH-DAMP

LINK-ZC-ADP

FLEX-CNCT

DV-46DVA-GK

Figure 8.9 Direct Vent Flex Liner Accessory Kits

G. Alternate Venting Configurations Using Adaptation to SLP Venting

This model is approved to use SLP Series flue pipe com- ponents. A SLP-TVHWvertical Termination Cap must be used for vertical terminations. A SLP-TRAP2 can be used for horizontal terminations.

Approved flue system components are labeled for identifi- cation. NO OTHER FLUE SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are in- cluded with each flue termination kit and should be used in conjunction with this manual.

WARNING! Risk of Fire! This gas appliance and flue assembly must be flued directly to the outside and must never be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate flue system-common flue systems are prohibited.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping material could ignite and will in- terfere with proper operation of doors and louvers.

Horizontal sections 3 in. (76 mm) from the top of the pipe.

Horizontal sections 2-1/2 in. (64 mm) at wall shield firestops.

Horizontal sections 1 in. (25 mm) from sides and bottom of the pipe.

Vertical sections 1 in. (25 mm) on all sides of pipe.

Failure to keep insulation or other material away from vent pipe may cause over heating and fire.

For alternative installations, other than depicted, contact your dealer for further information.

28

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12