Heat & Glo LifeStyle SUPREME-N-I30AU owner manual Clearance to non-combustible back, 19 in. 482 mm

Models: SUPREME-P-I30AU SUPREME-N-I30AU

1 60
Download 60 pages 51.13 Kb
Page 33
Image 33

NOTE: Any 3 in. (76 mm) section of flex pipe must be enclosed to existing fireplace flue in double lined flue to comply with AS2918-2001 and the building code of Australia.

3-3/8 in.

(85 mm) Ø FLEX FLUE

A

Clearance to non-combustible back

19 in. (482 mm)

B

Clearance from non-combustible back

4 in. (101 mm)

to combustible material

 

 

C

Clearance to non-combustible header

26 in. (660 mm)

D

Clearance to non-combustible top

40 in. (1016 mm)

SLP-TVHW

Must adhere to pipe clearances.

SLP 170 Ø

 

 

 

MINIMUM TOTAL

 

 

 

FLUE RUN 10 ft. (3 m)

Colinear to Coaxial Adapter

 

 

 

 

 

 

 

 

LINK ADAPTER

 

 

225 & 275 Ø GALVANIZED FLUE

 

MAXIMUM TOTAL

 

 

 

FLUE RUN 51 ft. (15.5 m)

 

 

 

 

DOUGBLE SPIGOT STARTER PLATE, FIXED TO HEBEL TO ACCOMODATE 225 AND 275 Ø FLUES

HEBEL BLOCKS 600 X 200 X 75

Figure 8.16

MINIMUM FLEX FLUE RUN TOP OF BOX SPIGOT TO LINK ADAPTER 35-7/16 in. (900 MM)

MINIMUM 1/4 in. (6 mm)

NON-COMBUSTIBLE BASE (UNDER UNIT)

Seal connection points for duct- ing. Sealant must have a minimum explosure rating of 649 °C (1200° F).

NOTE: Tape all SLP pipe connec- tions with aluminum foil tape rated to a minimum of 149 °C (300 °F).

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

33

Page 33
Image 33
Heat & Glo LifeStyle SUPREME-N-I30AU Clearance to non-combustible back, 19 in. 482 mm, Clearance from non-combustible back