Heat & Glo LifeStyle SUPREME-P-I30AU, SUPREME-N-I30AU Finishing, A. Mantel and Wall Projections

Models: SUPREME-P-I30AU SUPREME-N-I30AU

1 60
Download 60 pages 51.13 Kb
Page 46
Image 46

11 Finishing

A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).

Clearance to combustible material under the insert is 1/4 in. (6 mm). Clearance from top of fireplace opening for combustibles extending 12 in. (305 mm) max. is 12 in. (305 mm).

Use leveling legs to raise insert minimum 1/4 in. (6 mm) above combustible material or outer wrap of factory built firebox.

Combustible facings must not extend behind the insert surround. For non-combustible material specifications refer to section 1.E.

NON-COMBUSTIBLE FACING

 

12 in.

 

(305 mm)

 

MAX.

 

MINIMUM CLEARANCE

TO COMBUSTIBLE

12 in.

MANTEL OR

(305 mm)

PROJECTION

MIN.

Figure 11.1 Clearances to Mantels or other Combustibles above Appliance

46

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12