Heat & Glo LifeStyle SUPREME-N-I30AU, SUPREME-P-I30AU owner manual Model, Flue Termination Approval

Models: SUPREME-P-I30AU SUPREME-N-I30AU

1 60
Download 60 pages 51.13 Kb
Page 27
Image 27

TABLE 1

 

MODEL

FLUE TERMINATION APPROVAL

SUPREME-N-I30AU, SUPREME-P-I30AU

LINK-DV30B VERTICAL TERMINATION CAP

TERMINATION CAP

CHIMNEY PLATE (MADE TO ORDER)

EXHAUST

INLET AIR

COLLAR

COLLAR

 

WARNING: THE EXHAUST PIPE MUST ONLY BE CONNECTED TO THE EXHAUST STARTING COLLAR OF THE UNIT AND THE EXHAUST COLLAR OF THE TERMINATION CAP.

THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR COLLAR OF THE UNITAND ATTACHED TO THE INLET AIR COLLAR OF THE TERMINATION CAP. THE APPLIANCE WILL NOT OPERATE PROPERLY IF INCORRECTLY CONNECTED.

THIS IS A BALANCED FLUE HEATER AND REQUIRES THE USE OF BOTH FLUE LINERS AND MUST TERMINATE TO THE CAP.

SLP-TVHW

FLEXIBLE FLUE

MINIMUM TOTAL FLUE

RUN 10 ft. (3 m)

MAXIMUM 39 ft. (12 m)

MINIMUM 1/4 in. (6 mm )

NON-COMBUSTIBLE BASE (UNDER UNIT)

Figure 8.8

Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU2222-900 Rev. P • 6/12

27