Heat & Glo LifeStyle VRT-GY-P-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB C. Maintenance Tasks, Inspect

Models: VRT-BZ-P-AUB VRT-GY-N-AUB VRT-BZ-N-AUB VRT-GY-P-AUB

1 75
Download 75 pages 49.02 Kb
Page 69
Image 69

C. Maintenance Tasks

Inspect

 

Maintenance Tasks

 

 

Doors

1. Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

2.

Verify no obstructions to airflow.

 

 

 

 

3.

Verify maintenance of proper clearance to combustible household objects.

 

 

Gasket Seal, Glass

1. Inspect gasket seal and its condition.

Assembly and Glass

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

 

 

 

 

 

3.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

4. Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact

 

 

and operating properly. Replace as necessary.

 

 

 

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.

 

 

Valve Compartment

1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips

and Firebox Top

 

that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

Logs

1. Inspect for broken, damaged, or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

Firebox

1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.

 

 

 

 

2.

Replace appliance if firebox has been perforated.

 

 

Burner Ignition and

1. Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

 

 

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.

 

 

 

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

9. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery

 

 

cloth or replace as required.

Flueing

1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks, fences or sheds)

 

 

has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

 

Remote controls

1. Verify operation of remote.

 

 

 

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

 

Heat & Glo • VRT-AUB2123-980 Rev. H • 5/12