| Model 590/592 |
| This is an |
| held in the frypot. The solenoid valve closes at the beginning |
| of the Cook Cycle and opens automatically at the end of the |
| Cook Cycle. If this valve should become dirty, or the Teflon |
| seat nicked, pressure will not build up. The electric fryer uses a |
| 208/240 volt 60 hertz coil (50 hertz internationally). |
To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
Coil Check Procedure
Remove the solenoid wires from the wire nuts which are found behind the control panel. Check across wires.
| RESULTS |
208/240 Volt, 60 Hertz | 150 Ohms |
208/240 Volt, 50 Hertz | 230 Ohms |
Replacement
1.Remove the right side panel.
2.Remove the
3.Remove the cover.
4.If only the coil is to be replaced, disconnect two coil wires at wire nuts in the coil housing. Remove coil, insert new coil, and connect wires at wire nuts. Assemble in reverse order of disassembly.
The wires may be connected in any order.