Henny Penny 590, 592 manual Solenoid Valve, Replacement

Models: 592 590

1 25
Download 25 pages 34.46 Kb
Page 12
Image 12

 

Model 590/592

2-15. SOLENOID VALVE

This is an electro-mechanical device that causes pressure to be

 

held in the frypot. The solenoid valve closes at the beginning

 

of the Cook Cycle and opens automatically at the end of the

 

Cook Cycle. If this valve should become dirty, or the Teflon

 

seat nicked, pressure will not build up. The electric fryer uses a

 

208/240 volt 60 hertz coil (50 hertz internationally).

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

Coil Check Procedure

Remove the solenoid wires from the wire nuts which are found behind the control panel. Check across wires.

 

RESULTS

208/240 Volt, 60 Hertz

150 Ohms

208/240 Volt, 50 Hertz

230 Ohms

Replacement

1.Remove the right side panel.

2.Remove the “tru-arc” retaining clip on top of coil housing.

3.Remove the cover.

4.If only the coil is to be replaced, disconnect two coil wires at wire nuts in the coil housing. Remove coil, insert new coil, and connect wires at wire nuts. Assemble in reverse order of disassembly.

The wires may be connected in any order.

2-12

1103

Page 12
Image 12
Henny Penny 590, 592 manual Solenoid Valve, Replacement