Henny Penny 592, 590 manual Replacement

Models: 592 590

1 25
Download 25 pages 34.46 Kb
Page 5
Image 5

Model 590/592

2-6. POWER/PUMP SWITCH The POWER/PUMP switch is a three way rocker switch with a center OFF position. With switch in the POWER position, the fryer operates. With switch in PUMP position, the filter pump operates, but the unit will not heat.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

Checkout

1.Remove control panel.

2.Label and remove wires from the switch.

3.OFF position-should be open circuit anywhere on switch.

4.Power position. Check from:

5.Pump position. Check from:

#5 to #6 closed circuit #l to #2 closed circuit

#4 to #5 closed circuit #3 to #2 closed circuit

Check across the jumpers on the wires of POWER/PUMP switch. These jumpers have resistors and capacitors which may be faulty.

Replacement

1.With control panel removed, and wires off of the switch, push in on tabs on the switch to remove from the panel.

2.Replace with new switch, and reconnect wires to switch following the wiring diagram.

3.Replace the control panel.

1103

2-5

Page 5
Image 5
Henny Penny 592, 590 manual Replacement