Model 590/592
2-16. DEADWEIGHT VALVE (Continued)
ORIFICE CAP DEADWEIGHT
2-17. REMOVAL & CLEANING
OF SAFETY RELIEF VALVE
SAFETY RELIEF VALVE
DO NOT PULL THE RING ON THE SAFETY RELIEF VALVE. HOT STEAM WILL BE RELEASED AND SEVERE BURNS WILL RESULT.
1.At the end of each day’s usage of the fryer, the deadweight valve must be cleaned. The fryer must be OFF and pressure released. Open the lid and then remove the deadweight valve cap and deadweight.
Failure to clean the deadweight assembly daily could result in the fryer building too much pressure. Severe injuries and burns could result.
2.Wipe both the cap and weight with a soft cloth. Make certain to thoroughly clean inside cap, the weight seat, and around deadweight orifice.
3.Dry the parts and replace immediately to prevent damage or loss.
The safety relief valve should be cleaned once a year.
DO NOT ATTEMPT TO REMOVE SAFETY VALVE WHILE FRYER IS OPERATING, OR SEVERE BURNS OR OTHER INJURIES WILL RESULT.
1. Remove pressure gauge.
1103 |