Henny Penny 590, 592 manual If either contactor proves defective, replace as follows

Models: 592 590

1 25
Download 25 pages 34.46 Kb
Page 18
Image 18

Model 590/592

2-19. CONTACTORS (Continued)

To avoid electrical shock, make connections before applying power, take reading, and remove power before removing meter leads. The following checks are performed with the wall circuit breaker closed and the main power switch in the ON position.

4.With power reapplied and in a heat-up mode, check the power going to both contactor coils. This is to be sure power is going to the contactors.

If no voltage is found going into the primary contactor coil, check wiring, high limit, and drain switch. If no voltage at heat contactor coil, check wiring and connections at PC board.

Replacement

If either contactor proves defective, replace as follows:

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

1.Label and remove only those wires directly connected to the contactor being replaced.

Hint: Removing the left side panel may be helpful in replacing the heat contactor.

2.Remove the mounting screws on the base plate of the primary contactor and remove contactor. Proceed to step 5.

3.Remove the screws securing the mercury contactor bracket to the mounting plate and remove bracket and contactor.

4.Remove the screws securing the contactor to the bracket and remove contactor from bracket.

5.Install new contactor in reverse order.

6.Install control panel and reconnect power to the fryer and

test for proper operation.