3.S-REGISTERS

The S-Registers are summarized in the table below along with their default values; registers may be stored in one of the two user profiles by entering the &Wn command.

Register designations can be easily changed by modifying the modem sources.

The appropriate AT command which controls the relevant bits in the S-Register should be used to change the value.

3.1.DEFAULT VALUES

The "factory" default values are coded into the modem tables and set into the active configuration at initialization or by the ATZn command. The designated default profile is subsequently loaded, and may change some of the factory default values. The designated default profile can be changed by entering the &Yn command where n is one of the two possible user profiles.

The default values may be loaded at any time by entering the &Fn command.

Table 4-1. S-Register Summary

Register

Function

Range

Units

Default

S0

Rings to Auto-Answer

0-255

rings

0

S1

Ring Counter

0-255

rings

0

S2

Escape Character

0-255

-

43 (+)

 

 

 

 

 

S3

Carriage Return Character

0-127

-

13 CR

S4

Line Feed Character

0-127

-

10 LF

S5

Backspace Character

0-255

-

8 BS

S6

Wait Time for Dial Tone

2-255

s

2

S7

Wait Time for Carrier

1-255

s

50

S8

Pause Time for Dial Delay Modifier

0-255

s

2

S11

DTMF Tone Duration

50-255

ms

95

S12

Escape Guard Time

0-255

0.02 s

50

S36

LAPM Failure Control

0-7

-

7

S37

Line Connection Speed

0-18

-

0

S38

Delay Before Forced Hangup

0-255

s

1

S83

LAPM Detection Timeout

1-30

s

10

3.2.S-REGISTER DEFINITIONS

S0 - Number of Rings to Auto-Answer

Sets the number of the rings required before the modem automatically answers a call. Setting this register to zero disables auto-answer mode.

Range: 0-255 rings

Default: 0

S1 - Ring Counter

S1 is incremented each time the modem detects a ring signal on the telephone line. S1 is cleared if no rings occur over an eight second interval.

Range: 0-255 rings

Default: 0

48

Page 49
Image 49
Hitachi HPW-200EC manual S0 Number of Rings to Auto-Answer, S1 Ring Counter