Hitachi NB616X instruction manual If they

Models: NB616X

1 32
Download 32 pages 58.72 Kb
Page 13
Image 13

Chapter 4 WIRING AND CONNECTION

(Note 3) : Please separate the main circuit wiring from the relay control circuit wiring.

If they

Power cables

R, S, T, U, V, W, P, PD,

 

 

RB, N, R0, T0 etc.

 

Right angle

 

 

Input/Output signal lines

Control signal of STAT, ORT, LAC, PCLR, SAP, SAN, SBP, SBN,

EAP, EAN, EBP, EBN, POK, DSE, ZS, AP, AN, BP, BN, L, EP5,

EG5, CM1, CM2, P24, PLC etc.

Separate it 10cm or more.

have to be crossed, be sure that they must be crossed at right angle.

(Note 4) : Don’t make a short circuit between the EP5 and EG5 terminals. There is a danger of malfunctions.

(Note 5) : Isolate common signal for analog signal of the main body (L terminal of the logic card of SJ300) from common terminal of the SJ-FB.

(Note 6) : Please connect the encoder signal line properly so that the relationship among their phases become as shown below during rotation of the motor(Standard EG5).

EAP

EAN

EBP

EBN

EZP

EZN

13