Hitachi NB616X Pulse train mode selection, Forward/Reverse command + pulse train mode

Models: NB616X

1 32
Download 32 pages 58.72 Kb
Page 28
Image 28

Chapter 7 FUNCTIONS

7.3.4 Pulse train mode selection

The following 3 ways of pulse line input can be selected by the setting of P013. 1) 90° phase difference pulse train (Mode 0)

SAP

SAN (Pulse train input)

SBP

SBN (Pulse train input)

Detected

pulse number

Forward

Reverse

Time

2) Forward/Reverse command + pulse train (mode 1)

SAP SAN

(Pulse train input)

SBP

SBN (Forward/reverse command)

Detected

 

pulse number

 

Forward

Reverse

 

 

Time

3) Forward pulse train + Reversion pulse train (mode 2)

SAP

SAN

(Forward pulse train input)

SBP

SBN

(Reverse pulse train input)

Detected

 

pulse number

 

Forward

Reverse

28

Time

 

Page 28
Image 28
Hitachi NB616X instruction manual Pulse train mode selection, Forward/Reverse command + pulse train mode