Chapter 7 FUNCTIONS

7.3.4 Pulse train mode selection

The following 3 ways of pulse line input can be selected by the setting of P013. 1) 90° phase difference pulse train (Mode 0)

SAP

SAN (Pulse train input)

SBP

SBN (Pulse train input)

Detected

pulse number

Forward

Reverse

Time

2) Forward/Reverse command + pulse train (mode 1)

SAP SAN

(Pulse train input)

SBP

SBN (Forward/reverse command)

Detected

 

pulse number

 

Forward

Reverse

 

 

Time

3) Forward pulse train + Reversion pulse train (mode 2)

SAP

SAN

(Forward pulse train input)

SBP

SBN

(Reverse pulse train input)

Detected

 

pulse number

 

Forward

Reverse

28

Time

 

Page 28