Hitachi NB616X instruction manual Set Motor constant J bigger and bigger H024/H034

Models: NB616X

1 32
Download 32 pages 58.72 Kb
Page 20
Image 20

Chapter 6 OPERATION

(Note 6) : If satisfactory performance can not be obtained, please adjust the motor constant for the phenomena according to following table.

Status

of

Phenomena

Contents of adjustment

Adjusting

running

 

parameter

 

 

 

 

 

At starting

 

The

shock

is

Set “Motor constant J” bigger and bigger

H024/H034

 

 

occurred at starting

slowly until 1.2 times for preset constant.

 

At

 

Unstable

of

motor

Set speed response smaller.

H005

 

Set “Motor constant J” smaller for preset

 

deceleration

rotation

 

 

H024/H034

 

 

Constant.

 

 

 

 

 

 

During

 

Insufficient

torque

Set overload restriction level lower than torque

b021

torque limit

during torque limit at

limit level￿

b041-b044

 

 

low speed

 

 

 

At low

 

 

 

 

Set “Motor constant J” bigger for preset

 

frequency

 

Irregular of rotation

H024/H034

operation

 

 

 

 

constant.

 

 

 

 

 

 

 