Chapter 5 SETTING

5.3 Items regarding the feed back board of the inverter main body

 

 

 

 

 

 

 

 

Setting

Change

Code

 

 

Function name

Setting range

 

Initial data

mode on

 

 

 

 

 

 

 

 

on run

run

 

 

 

 

 

 

 

 

 

A044

1st

control method

00(VC) / 01(VP1.7power) / 02(Free V/f Setting)

00

-

-

 

 

 

 

 

/ 03(SLV) / 04(0Hz area SLV) / 05(V2)

 

 

 

H001

Auto-tuning

mode

00(NOR : Invalid) / 01(NRT : not rotate)/ 02(AUT :

00

-

-

selection

 

rotate)

 

 

 

 

 

 

 

H002

1st

motor

constant

00(Hitachi standard motor constant)/

 

00

-

-

selection

 

01(Auto-tuning data)/

 

 

 

02(Auto tuning data with online auto-tuning)

 

 

 

 

 

 

 

 

 

 

 

H003

1st

motor

capacity

0.20 - 75.0(kW)

 

Setting on

-

-

selection

 

 

forwarding

 

 

 

 

 

 

H004

1st

motor

pole

2/4/6/8 (Poles)

 

4

-

-

selection

 

 

 

 

 

 

 

 

 

H005

1st

motor

speed

0.001 - 9.999 / 10.00 - 65.53

 

1.590

 

 

response setting

 

 

 

 

 

 

 

 

 

H006

1st

stabilized factor

0. - 255.

 

100.

 

 

 

1st motor R1 setting

 

 

depends on

 

 

H020

0.000 - 9.999 / 10.00 - 65.53(

)

the motor

-

-

 

 

 

 

 

 

 

capacity

 

 

 

1st motor R2 setting

 

 

depends on

 

 

H021

0.000 - 9.999 / 10.00 - 65.53(

)

the motor

-

-

 

 

 

 

 

 

 

capacity

 

 

 

1st motor L setting

 

 

depends on

 

 

H022

0.00 - 99.99 / 100.0 - 655.35(mH)

the motor

-

-

 

 

 

 

 

 

 

capacity

 

 

 

1st motor I0 setting

 

 

depends on

 

 

H023

0.00 - 99.99 / 100.0 - 655.35(A)

the motor

-

-

 

 

 

 

 

 

 

capacity

 

 

H024

1

st

motor J setting

0.000 - 9.999 / 10.00 - 99.99 /

 

depends on

 

 

 

the motor

-

-

 

100.0 - 9999.(kgm2)

 

 

 

 

 

 

 

 

capacity

 

 

H030

1st

motor R1 setting

0.000 - 9.999 / 10.00 - 65.53(

)

depends on

-

-

(Auto-tuning data)

the motor

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

H031

1st

motor R2 setting

0.000 - 9.999 / 10.00 - 65.53(

)

depends on

-

-

(Auto-tuning data)

the motor

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

H032

1st

motor L setting

0.00 - 99.99 / 100.0 - 655.35(mH)

depends on

-

-

(Auto-tuning data)

the motor

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

H033

1st

motor I0setting

0.00 - 99.99 / 100.0 - 655.35(A)

depends on

-

-

(Auto-tuning data)

the motor

 

 

 

capacity

 

 

 

 

 

 

 

 

 

 

 

15