Hitachi SJ-FB manual Data setting related to speed control

Models: SJ-FB

1 35
Download 35 pages 35.18 Kb
Page 25
Image 25

Chapter 7 FUNCTIONS

7.1.2 Data setting

Data setting related to speed control

Setting item

Function code

Setting Range, Setting Contents

Orientation speed setting (Note 1)

P015

0.00∼99.99 / 100.0∼120.0 (Hz)

 

 

 

Orientation direction setting (Note 2)

P016

0:Forward / 1:Reverse

 

 

 

(Note 1) : In order to stop the motor for setting position. (Motor takes 2 rotation to stop setting position)Don’t set high frequency to the orientation speed setting. Otherwise it will be over-voltage protection trip.

(Note 2) : Turn direction of the motor while orientation is done based on the setting of P016. Data setting related to position control

Setting item

Function

Setting range, setting contents

code

 

 

Orientation stop position(Note 3)

P014

0. ∼4095.

 

 

 

Completion range setting

P017

0∼9999. / 1000 (10,000) (pulses)

(Setting four times fairly of the encoder pulses)

 

 

Completion delay time (Note 4)

P018

0.00∼9.99

Position loop gain(Note 5)

P023

0.00∼99.99 / 100.0 (rad/s)

 

 

 

(Note 3) : The orientation stop position is to be set as 4096 of division (0∼4095) per 1 turn toward

 

forward from the original point. (It is 4096 division irrespective of the pulse number

 

of the encoder.) The original point is where the pulse has input to EZP-EZN.

 

Stoppage goal position is like shown in Figure 7-2 irrespective of the turn direction.

(Note 4)

: It depends on what type of main body combines with the SJ-FB, the setting value

 

conversion is different. Please refer to the (Note 3) of the “5.3 Items regarding the

 

feed back board of the inverter main body“.

(Note 5)

: To improve the positioning accuracy.

Increase position loop gain (G).

 

When the motor is unstable.

Decrease position loop gain.

Z pulse Position

(Reference point) 0

Motor Shaft viewed from the load side

10243072

2048

Figure 7-2 Concept of Orientation setting Position